FF-1319A-13E usa jmk inc 15 caldwell dr. amherst, nh 03031 p h: 603 886-4100 fx: 603 886-4115 email: info@jmkfilters.com eur jmk inc glasgow g13 1dn scotland uk ph: 44-(0) 7785310729 fax: 44-(0) 141 589 1884 operating voltage = _________________dc to 270 vac operating current (max) = ________________ 13 amps operating frequency = ___________________50/60 hz operating temperature (storage) = _______ -40 to 85 c operating temperature @ 13.0 a = _______ -40 to 65 c diel. withstanding voltage (ph - case) = ____ 1500 vac diel. withstanding voltage (ph - ph) = ______1500 vdc leakage current @ 270 vac, 60 hz = _____2.7 ma max discharge voltage after 60 sec = ___________34 v ma x transient suppression = ______ turn on (382?466) vd c total energy absorption = 140 joules / line (10x100 0 us) calculated mtbf = ________2,278,890 hrs @ 30c gb this filter has been designed to operate with the v icor "vi- hamd / bamd harmonic attenuator modules" to meet en55022, class b. this is a special model with a modified form factor , raychem 44a0111 wire leads and a wide operating range from ?40c to +65c. this model also has varistors inserted in order to suppress transients between line and neutral and al so between the power leads and ground. order p/n: FF-1319A-13E insertion loss vs. frequency wire # ref 001 line (l1) 002 load 003 neut (l2) 004 load 005 earth
|